Electrical UL/CSA
Electrical UL/CSA > SCCR Solutions

SCCR Solutions

When working with panel Short-Circuit Current Rating markings there are some common issues.  Certain components can be very limiting to your overall panel rating, and the method of calculating the panel rating itself can be confusing.  Cooper Bussmann has addressed both of these issues with the products, services and programs found below.  The Cooper Bussmann award-winning OSCAR™ compliance software is a tool that calculates assembly SCCR ratings based on component information.

OSCAR<>&trade</>OSCAR™ SCCR Compliance Software

The method of calculating panel Short-Circuit Current Rating based on UL 508A supplement SB can be quite confusing.  The award-winning OSCAR™ compliance software can calculate panel withstand ratings for marking based on component information and the methodology from UL 508A supplement SB.

Panel ReviewSCCR Panel Design Review

If you have worked through your panel design and find your SCCR needs improvement, contact the Cooper Bussmann engineering services team for a design review. We guarantee our panel design and review service for UL508A Supplement SB pre-certification.  To contact our engineering team click here.

Compact Circuit ProtectorCompact Circuit Protector - CCP

The Compact Circuit Protector or CCP offers an unprecedented 200kA short-circuit current rating (SCCR), using just 1/3 of the space of equivalent rated circuit breakers and 2/3 the space required by a traditional fusible switch.  The CCP also retains a best-in-class full voltage rating of 600Vac.

High SCCR Data SheetHigh SCCR Power Distribution & Terminal Blocks

This data sheet contains a combination of application material for terminal and power distribution blocks along with detailed product specifications.  An all-in-one document for information on Cooper Bussmann PDBs and Terminal Blocks with High SCCR Ratings.

High SCCR ComponentsHigh SCCR Overcurrent Protective Devices

When calculating panel ratings overcurrent protective devices can seriously limit the overall withstand.  Using branch and feeder protective devices with high short-circuit current ratings can help raise the panel rating.

High SCCR PDBsHigh SCCR Power Distribution Blocks

Due to the low default withstand of Power Distribution Blocks they can often be a limiting factor to a high panel rating.  To address this issue Cooper Bussmann has manufactured a selection of PDBs with 100 & 200kA withstand ratings.

Finger-Safe PDBsEnclosed High SCCR Power Distribution Blocks

IP20 Finger-Safe Power Distribution Blocks with high SCCR can help to raise assembly withstand ratings and increase worker safety.